Full Stage Setup Process

  • Mount the tracker to the camera, using a repeatable mount (like a cinelock, not a noga arm.)
  • Move the camera to your stage 0 point, and zero in RF
  • Measure the distance in meters from your trackers datum to the floor, enter this in "Tracker->floor distance" in RF
  • Your camera should now be properly positioned in RF.

Zero the tracker while it is on your camera, otherwise any error in the mount will cause the tracker to move at an angle